TEST DATA BY STROKE

Table No. 2

DESCRIPTION OF SAMPLE TEST DIMENSION RODS IN MM BEFORE TEST MAXIMUM LOAD STRENGHT KLASSIFICATION OF FOLD
  d
a x b
AREA OF PROFILE (mm2) A Rm
MPa
 
1.1 0.8x12.3 9.84 2930 298 PM
1.2 0.8x12.3 9.84 2900 295 PM
2.1 0.8x12.2 9.76 2880 295 PM
2.2 0.8x12.3 9.84 2860 291 PM
3.1 0.8x12.2 9.76 2830 290 PM
3.2 0.8x12.3 9.84 2850 290 PM
4.1 0.8x12.2 9.76 2870 294 PM
4.2 0.8x12.2 9.76 2850 292 PM
5.1 0.8x12.2 9.76 2900 297 PM
5.2 0.8x12.2 9.76 2870 294 PM
6.1 0.8x12.3 9.84 2860 291 PM
6.2 0.8x12.3 9.84 2870 292 PM
10.1 0.8x12.2 9.76 2900 297 PM
10.2 0.8x12.3 9.84 2890 294 PM
11.1 0.8x12.3 9.84 2860 291 PM
11.2 0.8x12.3 9.84 2870 292 PM
13.1 0.8x12.3 9.84 2920 297 PM
13.2 0.8x12.3 9.84 2920 297 PM
14.1 0.8x12.3 9.84 2880 293 PM
14.2 0.8x12.3 9.84 2850 290 PM

 